Carrillo-Rodríguez, LilianaIbatá-Aristizabal, DanielLyons- Sebá, Laura A.Silva-Suárez, Nicolás A.Pulido-Medellín, Martín O.Balaguera-López, Helber E.Romero-Núñez, CamiloRoque-Rodríguez, Anita2019-06-162022-06-132019-06-162022-06-132019-06-160121-3709https://repositorio.unillanos.edu.co/handle/001/2720El ultrasonido es una técnica portátil y repetible, que permite evaluar de forma dinámica los movimientos del diafragma. Existen muchas causas que pueden generar disfunción diafragmática y parálisis diafragmática como anestésicos, injuria del nervio frénico, postoperatorio de cirugía cardíaca, torácica o abdominal, enfermedades neuromusculares, metabólicas e infecciosas y causas relacionadas al paciente crítico como sepsis y ventilación mecánica prolongada. Se tuvieron en cuenta cuarenta y ocho perros, entre internados y programados para cirugía electiva, sin signos clínicos cardiorrespiratorios a los cuales se les realizó ultrasonido Global FAST, se evaluó el movimiento del diafragma en modo M en tres posiciones y se registró la medida del índice de excursión diafragmática. Tres de los perros internados fueron excluidos, debido a hallazgos en el ultrasonido, los perros programados para cirugía electiva fueron sometidos al mismo protocolo preanestésico en los mismos tiempos. No se presentaron diferencias estadísticas entre las posiciones. Al comparar la medida del índice de excursión diafragmática entre los perros internados y anestesiados en la posición DLD (decúbito lateral derecho) y DD (decúbito dorsal), se observaron diferencias significativas (p<0,01). El ultrasonido en modo M es una buena herramienta para medir el índice de excursión diafragmática, proporciona información cuantitativa para la evaluación de la función dinámica diafragmática, la anestesia puede llegar a causar una disminucion significativa en el índice de excursión diafragmático, el cual puede permanecer oculto y generar complicaciones anestésicas.The ultrasonographic examination is a portable, non-invasive, repeatable technique that can assess the dynamic movements of the diaphragm. There are several causes for diaphragmatic dysfunction or paralysis, including anesthetic drugs, phrenic nerve injury, postoperative cardiac, thoracic or abdominal surgery; neuromuscular, infectious or metabolic diseases, critical patient comorbidities such as sepsis or prolonged mechanical ventilation complications. The study included forty-eight dogs that where either hospitalized or admitted for elective surgery without cardiorespiratory disease signs. They were evaluated following Global FAST protocol. The diaphragmatic movement was evaluated in M mode and the excursion diaphragmatic index was measured in three different positions. Three dogs were excluded due to their ultrasonographic findings. The same anesthetic protocol was used for the dogs admitted for elective surgery. There was no statistical difference between the dogs evaluated in the three different positions. The excursion diaphragmatic index of the hospitalized dogs compared to anesthetized dogs in right lateral recumbency (RLR) and dorsal recumbency (DR) was significantly different (p <0,01). Mode M ultrasonographic examination is a useful tool to measure the excursion diaphragmatic index in dogs because it provides quantitative information for the evaluation of the dynamic function of the diaphragm. Anesthetic drugs can cause a significant reduction of the excursion diaphragmatic index which, if not evaluated and detected promptly, can cause complications anesthetic.application/pdfspaOrinoquia - 2019Organic residuescompostingmanagement of residuesclean productionResiduo orgánicocompostajegestión de residuosproducción limpiaEvaluación del movimiento diafragmático por ultrasonografía mediante la medición del índice de excursión en perrosArtículo de revistainfo:eu-repo/semantics/openAccess10.22579/20112629.5422011-2629https://doi.org/10.22579/20112629.542Evaluation of diaphragmatic movement measuring the excursion index with ultrasonography in dogshttp://purl.org/coar/access_right/c_abf2